Current transformer is used to step down the higher current in primary and
protects the measuring instruments against high currents. Low Voltage
Transformers are used for supply to measuring instruments & protection devices
of electrical switchgear and control gears installation.
Technical data
Two types of CT are available- Moulded case Current transformer and Split
Core Current Transformer.
Mounded case current transformers are used if high currents are to be
recorded and further processed
Available in wide range from 40A to 6000A suitable to be used in all
applications
Split core CTs suitable to be used into an existing installation without any
additional mounting requirements.
Available up to 5000A Primary current
Casing - Non-flammable, self-extinguishing ABS / PC
Unbreakable plastic housing of polycarbonate, Self-extinguishing, UL94-V0
and flame resistant
Nickel-plated secondary terminals & Integrated Secondary Locking Caps for
all CTs.
Analog Meters are used in panels to measure electrical parameters like current,
voltmeter, power factor, frequency etc.They display values on a dial, usually
with a moving pointer or needle.
Analog Voltmeters with size 72x72 and 96x96 are available
Analog Ammeters with size 72x72 and 96x96 are available
Analog MDI meter with size 72x72 and 96x96 are available
Analog Power factor Meter with size 72x72 and 96x96 are available
Analog frequency Meter with size 72x72 and 96x96 are available
Digital panel meters
Stefan digital panel meters are used for measurement and analysis of wide range
of electrical parameters
Supply Voltage 240 V AC
AC voltage: 100V, 250V, 400V
AC Current: 1A, 5A
Available in size 96x96
Available with RS 485 (MODBUS) Communication protocol
CT primary 5A – 10,000A (Programmable for any values)
Stefan Modular Contactors SB, SBM & SBX are used for commutation of Single Phase
& Three Phase low power electrical consumers. They can be combined with
auxiliary control, protection & indication functions. It can be used for remote
control application in alternative networks: Lighting, Heating, Ventilation
roller blinds, sanitary hot water, mechanical ventilation system, load-shedding
of non-priority systems etc.
Functions
Switching ON OFF consumers
Making of control systems
Remarkable with high reliability of current characteristics
Reliable switching ON or separation of Power Contacts.
This particular limit switch has been developed by Stefan Electric in order to
fulfill all the requests coming from applications in which there is the
necessity to simulate the changeover in contacts position without acting
directly, on the plunger of the switch. The use of this device is particularly
useful in the realization of electrical boards in order to simulate the closing
of the door simply by pushing the yellow button on the limit switch; the
assigned staff will then be able to work on the internal circuit to make
modifications, maintenance, etc... The conditions of normal operation are
automatically restored once the door of the electric board is closed.
Stainless punch and spring
No positioning limit. Electrically separated contacts
Precise operating points (consistency)
Replaceable Snap action contacts
Immune to electromagnetic disturbances
Water-proof and Oil-proof construction
Double spring mechanism ensure longer mechanical life
Casing material Plastic
Rated current at 250V AC15 6A
Rated insulation voltage Ui 690V
Rated impulse withstands voltage Uimp 6kV
Protection against electrical shocks (IEC 61140) II
Protection degree EN60529 IP65
Mounting positions All position is authorized
Applicable standards IEC 947-5-1 & EN 60947-5-1
Stefan relays
Earth leakage relays
Earth leakage relays with trip levels 0.03-3A
Configurable Earth leakage Time delay from 0-10 S
Available in two types Din Rail Mount and Panel Mount
Core Balance Current Transformer with diameter 35mm,50mm,70mm,120mm,150mm,
210mm also, 115x305mm Rec and 150x350mm Rec are available
LED indication for relay status, CT open, Earth leakage fault & Test/Reset
switch feature
Under voltage relays
A relay that has contacts that operate when the voltage drops below a set
voltage. Undervoltage relays are used for protection against voltage drops,
to detect short-circuit faults, etc. The main function of the relay is to
sense or detect the abnormalities in the circuit and to send a message to
circuit breaker to break the circuit. In case of undervoltage relay if the
voltage in the circuit or system is less than prescribed value it will
disconnect the circuit with the help of circuit breaker.